200S 53
I - 4 Turning Specific Operations
Enabling Z
0
, and Z Coupling
To couple the Z
0
, and Z axes and have the result displayed on the Z
0
display, press and hold the Z
0
key approximately 2 seconds. The sum
of the Z positions will be displayed on the Z
0
display and the Z display
will be blanked.
To couple the Z
0
, and Z axes and have the result displayed on the Z
display, press and hold the Z key for approximately 2 seconds. The
sum of the Z positions will be displayed on the Z display and the Z
0
display will be blanked. The coupling is preserved in between
power cycles.
Moving either Z
0
, or Z inputs will update the coupled Z position.
When a position is coupled, the reference mark for both encoders
must be found in order to recall the previous datum.
Disabling Z
0
, and Z Coupling
To disable Z Coupling, press the axis key of the display that is blank.
The individual Z
0
, and Z display positions will be restored.